SepticRecord

Lake County

Septic services in Mentor, Ohio

Operators based within 12 miles of Mentor

Listed by where the business is, not by who it says it serves. Every operator here was on the ODH 2026 sewage treatment system bond lists on the date its record shows, and the address it is placed by comes from that same list, so this is a checkable claim rather than a service-area promise. An Ohio bond covers work in any health district in the state, though each district registers its contractors separately, so operators further out can work here too; these are simply the ones closest to you.

Tj Smith Excavating LLC

On the state bond list for 2026

Septic System Repair · Septic Installation

Phone
not on file
Website
none

Soil and septic suitability around Mentor

The USDA has already rated this ground for exactly one use: a septic tank absorption field. Within 4 miles of Mentor — 28,017 acres across 47 soil map units — it rates 85.5% of the land very limited for that use and 0% somewhat limited, and almost none with no limitation at all.

What the limitation actually is

A rating on its own tells you nothing you can act on. The reasons do, and around Mentor the leading one is depth to saturated zone on 68.2% of the mapped area, followed by slow water movement on 52.1%. In full:

Limiting featureShare of areaWhat it means on site
Depth to saturated zone68.2%A seasonal water table sits too close to the surface
Slow water movement52.1%Water moves through the soil too slowly for a drain field to keep up
Seepage, bottom layer22.7%The layer beneath the trench is porous enough that effluent could reach groundwater without being filtered
Filtering capacity20.3%The soil drains so fast it would not filter the effluent
Slope5.7%The ground is too steep for a conventional field

Shares overlap: most soils here are limited for more than one reason at once, so these do not sum to 85.5%.

The soils themselves

The named soils and land types that make up most of the ground around Mentor. Conneaut alone accounts for 26.5% of it.

Soil or land typeShareDrainageSlopeDepth to bedrockSeptic rating
Conneaut26.5% Somewhat poorly drained 0 to 4% None in profile Very limited
Tyner13% Well drained 1 to 12% None in profile Very limited
Painesville12% Somewhat poorly drained 0 to 2% None in profile Very limited
Red Hook8.3% Somewhat poorly drained 0 to 2% None in profile Very limited
Platea7% Somewhat poorly drained 0 to 12% None in profile Very limited

“None in profile” means SSURGO records no bedrock or other restrictive layer within the depth it describes, not that none exists.

Area of interest: a 4-mile radius around the USGS Geographic Names centre point for Mentor (GNIS 1086425, 41.6902, -81.3359), chosen because five of this state's communities are unincorporated and have no boundary to use, and because the lots that need a septic permit are in the ring around a town rather than inside it. Soil from USDA-NRCS Soil Data Access, SSURGO interpretation “ENG - Septic Tank Absorption Fields”, area-weighted by mapped acreage and by each component's share of its map unit. Survey areas: Lake County, Ohio (2025-09-02). Retrieved 2026-09-18.

This is a survey, not an evaluation of your lot. The permit decision rests on the site evaluation ODH carries out for the specific parcel.

By service

Permitting in Lake County

In Lake County a septic (sewage treatment system) permit is issued by the local board of health, not by the state. The Ohio Department of Health writes the rules; the health district applies them and registers the contractors who work in it. See the Lake County detail →