Dale Jerrolds Backhoe & Dozer
Verified against state license rosterSeptic Installation · Septic System Repair
- Phone
- 731-607-7218
- Website
- none
Hardin County
Listed by where the business is, not by who it says it serves. Every operator here holds a current state permit, and the address it is placed by comes from the state's own published list — so this is a checkable claim rather than a service-area promise. A Tennessee installer permit is valid statewide, so operators further out can work here too; these are simply the ones closest to you.
Septic Installation · Septic System Repair
Septic Installation · Septic System Repair
Septic Installation · Septic System Repair
Septic Installation · Septic System Repair
Septic Installation · Septic System Repair
Septic Installation · Septic System Repair
Septic Installation · Septic System Repair
Septic Installation · Septic System Repair
Septic Installation · Septic Tank Pumping · Septic System Repair
Septic Installation · Septic System Repair
Septic Installation · Septic Tank Pumping · Septic System Repair
The USDA has already rated this ground for exactly one use: a septic tank absorption field. Within 4 miles of Nixon — 32,005 acres across 125 soil map units — it rates 78.7% of the land very limited for that use and 11.1% somewhat limited, and almost none with no limitation at all.
A rating on its own tells you nothing you can act on. The reasons do, and around Nixon the leading one is depth to saturated zone on 45.3% of the mapped area, followed by slow water movement on 32.1%. In full:
| Limiting feature | Share of area | What it means on site |
|---|---|---|
| Depth to saturated zone | 45.3% | A seasonal water table sits too close to the surface |
| Slow water movement | 32.1% | Water moves through the soil too slowly for a drain field to keep up |
| Slope | 28.4% | The ground is too steep for a conventional field |
| Flooding | 28.2% | The site floods often enough to matter |
| Seepage, bottom layer | 21.7% | The layer beneath the trench is porous enough that effluent could reach groundwater without being filtered |
Shares overlap: most soils here are limited for more than one reason at once, so these do not sum to 89.8%.
The named soils and land types that make up most of the ground around Nixon. Saffell alone accounts for 12.8% of it.
| Soil or land type | Share | Drainage | Slope | Depth to bedrock | Septic rating |
|---|---|---|---|---|---|
| Saffell | 12.8% | Well drained | 5 to 45% | None in profile | Very limited |
| Paden | 8.4% | Moderately well drained | 0 to 12% | None in profile | Very limited |
| Luverne | 8.2% | Well drained | 5 to 45% | None in profile | Very limited |
| Smithdale | 8.1% | Well drained | 5 to 45% | None in profile | Very limited |
| Wolftever | 8% | Moderately well drained | 0 to 10% | None in profile | Very limited |
“None in profile” means SSURGO records no bedrock or other restrictive layer within the depth it describes, not that none exists.
Some of the ground around Nixon carries a water table that rises close to the surface for part of the year and is nowhere to be seen for the rest of it. A field built into saturated soil does not treat effluent and does not drain, and the soil does not have to be wet on the day it is looked at for that to be true — the evidence is in the profile, as mottling and grey colours, which is one of the reasons the work is done by someone trained to read a soil pit rather than by timing water in a hole in August.
The ground around Nixon holds water. Tennessee measures this as an absorption rate in minutes per inch, and slow soil does not fail a site so much as enlarge it: the slower the rate, the more trench length the same household needs, and past a point a conventional field stops being approvable at all. A slow site is normally still buildable on a low-pressure pipe or drip design, and that is the point at which the installer list matters, because most licence holders in Tennessee are not endorsed for either.
A drain field has to be close to level. Effluent is distributed along a trench by gravity or by pump, and on a grade it runs to the low end, overloads it, and surfaces there. Around Nixon enough of the ground is steep that field placement tends to decide house placement rather than the other way round — the usable field area is often a bench or a shoulder some distance from the best building site, and the connection between them is a cost. It is worth knowing which part of a lot is the field before you fall in love with a view.
Area of interest: a 4-mile radius around the USGS Geographic Names centre point for Nixon (GNIS 1295773, 35.1148, -88.2567), chosen because five of this state's communities are unincorporated and have no boundary to use, and because the lots that need a septic permit are in the ring around a town rather than inside it. Soil from USDA-NRCS Soil Data Access, SSURGO interpretation “ENG - Septic Tank Absorption Fields”, area-weighted by mapped acreage and by each component's share of its map unit. Survey areas: Hardin County, Tennessee (2025-08-28). Retrieved 2026-09-09.
This is a survey, not a soil map for your lot. A permit needs a high-intensity map of the specific parcel, produced by a TDEC-approved soil consultant — see soil map vs perc test.
Septic permitting in Hardin County is administered by the State of Tennessee, not the county health department. See the Hardin County detail →